{"id":679,"date":"2024-07-31T13:52:35","date_gmt":"2024-07-31T13:52:35","guid":{"rendered":"https:\/\/safegasequipment.co.za\/?page_id=679"},"modified":"2024-07-31T15:54:00","modified_gmt":"2024-07-31T15:54:00","slug":"679-2","status":"publish","type":"page","link":"https:\/\/safegasequipment.co.za\/index.php\/679-2\/","title":{"rendered":""},"content":{"rendered":"\n<p class=\"has-white-color has-vivid-cyan-blue-background-color has-text-color has-background has-medium-font-size\"><strong>Type Examination Certificate<\/strong><\/p>\n\n\n\n<p>Example of Test Type Examinations Certificates issued by different Notified Bodies.<\/p>\n\n\n\n<p>The following to be noted on such a certificate:<\/p>\n\n\n\n<ul>\n<li>Notified Body name, number and logo<\/li>\n\n\n\n<li>Certificate number<\/li>\n\n\n\n<li>Name of Manufacturer<\/li>\n\n\n\n<li>Product Type<\/li>\n\n\n\n<li>Product Range\/Series<\/li>\n\n\n\n<li>Product Sizes<\/li>\n\n\n\n<li>Testing Standards<\/li>\n\n\n\n<li>Directive\/Regulation used<\/li>\n\n\n\n<li>Signed and dated by Notified body<\/li>\n\n\n\n<li>Validation of Certificate \u00b110 years<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"556\" height=\"746\" src=\"https:\/\/safegasequipment.co.za\/wp-content\/uploads\/2024\/07\/Type-Examination-Certs-3.jpg\" alt=\"\" class=\"wp-image-651\" srcset=\"https:\/\/safegasequipment.co.za\/wp-content\/uploads\/2024\/07\/Type-Examination-Certs-3.jpg 556w, https:\/\/safegasequipment.co.za\/wp-content\/uploads\/2024\/07\/Type-Examination-Certs-3-224x300.jpg 224w, https:\/\/safegasequipment.co.za\/wp-content\/uploads\/2024\/07\/Type-Examination-Certs-3-200x268.jpg 200w\" sizes=\"(max-width: 556px) 100vw, 556px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"611\" height=\"762\" src=\"https:\/\/safegasequipment.co.za\/wp-content\/uploads\/2024\/07\/Type-Examination-Certs-2.jpg\" alt=\"\" class=\"wp-image-649\" srcset=\"https:\/\/safegasequipment.co.za\/wp-content\/uploads\/2024\/07\/Type-Examination-Certs-2.jpg 611w, https:\/\/safegasequipment.co.za\/wp-content\/uploads\/2024\/07\/Type-Examination-Certs-2-241x300.jpg 241w, https:\/\/safegasequipment.co.za\/wp-content\/uploads\/2024\/07\/Type-Examination-Certs-2-200x249.jpg 200w\" sizes=\"(max-width: 611px) 100vw, 611px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"643\" height=\"796\" src=\"https:\/\/safegasequipment.co.za\/wp-content\/uploads\/2024\/07\/Type-Examination-Certs-1.jpg\" alt=\"\" class=\"wp-image-650\" srcset=\"https:\/\/safegasequipment.co.za\/wp-content\/uploads\/2024\/07\/Type-Examination-Certs-1.jpg 643w, https:\/\/safegasequipment.co.za\/wp-content\/uploads\/2024\/07\/Type-Examination-Certs-1-242x300.jpg 242w, https:\/\/safegasequipment.co.za\/wp-content\/uploads\/2024\/07\/Type-Examination-Certs-1-200x248.jpg 200w\" sizes=\"(max-width: 643px) 100vw, 643px\" \/><\/figure>\n\n\n\n<p class=\"has-white-color has-vivid-cyan-blue-background-color has-text-color has-background has-medium-font-size\"><strong>Declaration of Conformity<\/strong><\/p>\n\n\n\n<p>Declaration of Conformity issued by the Manufacturer stating minimum requirements:<\/p>\n\n\n\n<ul>\n<li>Manufacturers name and logo<\/li>\n\n\n\n<li>Type Examination Certificate Number used for the type of equipment applied for<\/li>\n\n\n\n<li>Notified Body<\/li>\n\n\n\n<li>Standards tested against as per Type Examination Certificate<\/li>\n\n\n\n<li>Signed and date<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"692\" height=\"913\" src=\"https:\/\/safegasequipment.co.za\/wp-content\/uploads\/2024\/07\/DoC-1.jpg\" alt=\"\" class=\"wp-image-648\" srcset=\"https:\/\/safegasequipment.co.za\/wp-content\/uploads\/2024\/07\/DoC-1.jpg 692w, https:\/\/safegasequipment.co.za\/wp-content\/uploads\/2024\/07\/DoC-1-227x300.jpg 227w, https:\/\/safegasequipment.co.za\/wp-content\/uploads\/2024\/07\/DoC-1-200x264.jpg 200w\" sizes=\"(max-width: 692px) 100vw, 692px\" \/><\/figure>\n\n\n\n<p class=\"has-white-color has-vivid-cyan-blue-background-color has-text-color has-background has-medium-font-size\"><strong>Application form<\/strong><\/p>\n\n\n\n<p><strong>Section 1<\/strong>&nbsp;\u2013 Indicate if new application, renewal or modification to existing permit application<\/p>\n\n\n\n<p><strong>Section 2<\/strong>&nbsp;\u2013 Applicant Details&nbsp;<em>(the applicant is the sole legal entity to be recorded as the Permit Holder<\/em>&nbsp;with a domicile in SA)<\/p>\n\n\n\n<p><strong>Section 3<\/strong>\u00a0\u2013 Indicate if the Manufacturer has a Quality System or not and or used one or more Conformity Assessment Modules<\/p>\n\n\n\n<p><strong>Section 4<\/strong>&nbsp;\u2013 example<\/p>\n\n\n\n<figure class=\"is-layout-flex wp-block-gallery-1 wp-block-gallery has-nested-images columns-default is-cropped\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"806\" height=\"737\" data-id=\"646\"  src=\"https:\/\/safegasequipment.co.za\/wp-content\/uploads\/2024\/07\/Applicaiton-form-1.jpg\" alt=\"\" class=\"wp-image-646\" srcset=\"https:\/\/safegasequipment.co.za\/wp-content\/uploads\/2024\/07\/Applicaiton-form-1.jpg 806w, https:\/\/safegasequipment.co.za\/wp-content\/uploads\/2024\/07\/Applicaiton-form-1-300x274.jpg 300w, https:\/\/safegasequipment.co.za\/wp-content\/uploads\/2024\/07\/Applicaiton-form-1-768x702.jpg 768w, https:\/\/safegasequipment.co.za\/wp-content\/uploads\/2024\/07\/Applicaiton-form-1-200x183.jpg 200w\" sizes=\"(max-width: 806px) 100vw, 806px\" \/><\/figure>\n<\/figure>\n\n\n\n<p><strong>Section<\/strong>&nbsp;<strong>5&nbsp;<\/strong>\u2013 Only applicable to existing permits with upgrade or modification<\/p>\n\n\n\n<p><strong>Section 6<\/strong>&nbsp;\u2013 Terms and Conditions to be signed and dated<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Type Examination Certificate Example of Test Type Examinations Certificates issued by different Notified Bodies. The following to be noted on such a certificate: Declaration of Conformity Declaration of Conformity issued by the Manufacturer stating minimum requirements: Application form Section 1&nbsp;\u2013 Indicate if new application, renewal or modification to existing permit application Section 2&nbsp;\u2013 Applicant Details&nbsp;(the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v21.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>- Safe Gas Equipment Scheme<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/safegasequipment.co.za\/index.php\/679-2\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"- Safe Gas Equipment Scheme\" \/>\n<meta property=\"og:description\" content=\"Type Examination Certificate Example of Test Type Examinations Certificates issued by different Notified Bodies. The following to be noted on such a certificate: Declaration of Conformity Declaration of Conformity issued by the Manufacturer stating minimum requirements: Application form Section 1&nbsp;\u2013 Indicate if new application, renewal or modification to existing permit application Section 2&nbsp;\u2013 Applicant Details&nbsp;(the [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/safegasequipment.co.za\/index.php\/679-2\/\" \/>\n<meta property=\"og:site_name\" content=\"Safe Gas Equipment Scheme\" \/>\n<meta property=\"article:modified_time\" content=\"2024-07-31T15:54:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/safegasequipment.co.za\/wp-content\/uploads\/2024\/07\/Type-Examination-Certs-3.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/safegasequipment.co.za\/index.php\/679-2\/\",\"url\":\"https:\/\/safegasequipment.co.za\/index.php\/679-2\/\",\"name\":\"- Safe Gas Equipment Scheme\",\"isPartOf\":{\"@id\":\"https:\/\/safegasequipment.co.za\/#website\"},\"datePublished\":\"2024-07-31T13:52:35+00:00\",\"dateModified\":\"2024-07-31T15:54:00+00:00\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/safegasequipment.co.za\/index.php\/679-2\/\"]}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/safegasequipment.co.za\/#website\",\"url\":\"https:\/\/safegasequipment.co.za\/\",\"name\":\"Safe Gas Equipment Scheme\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/safegasequipment.co.za\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/safegasequipment.co.za\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/safegasequipment.co.za\/#organization\",\"name\":\"Safe Gas Equipment Scheme\",\"url\":\"https:\/\/safegasequipment.co.za\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/safegasequipment.co.za\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/safegasequipment.co.za\/wp-content\/uploads\/2019\/07\/cropped-SGES-Logo-TM_web-1.jpg\",\"contentUrl\":\"https:\/\/safegasequipment.co.za\/wp-content\/uploads\/2019\/07\/cropped-SGES-Logo-TM_web-1.jpg\",\"width\":250,\"height\":186,\"caption\":\"Safe Gas Equipment Scheme\"},\"image\":{\"@id\":\"https:\/\/safegasequipment.co.za\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"- Safe Gas Equipment Scheme","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/safegasequipment.co.za\/index.php\/679-2\/","og_locale":"en_US","og_type":"article","og_title":"- Safe Gas Equipment Scheme","og_description":"Type Examination Certificate Example of Test Type Examinations Certificates issued by different Notified Bodies. The following to be noted on such a certificate: Declaration of Conformity Declaration of Conformity issued by the Manufacturer stating minimum requirements: Application form Section 1&nbsp;\u2013 Indicate if new application, renewal or modification to existing permit application Section 2&nbsp;\u2013 Applicant Details&nbsp;(the [&hellip;]","og_url":"https:\/\/safegasequipment.co.za\/index.php\/679-2\/","og_site_name":"Safe Gas Equipment Scheme","article_modified_time":"2024-07-31T15:54:00+00:00","og_image":[{"url":"https:\/\/safegasequipment.co.za\/wp-content\/uploads\/2024\/07\/Type-Examination-Certs-3.jpg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/safegasequipment.co.za\/index.php\/679-2\/","url":"https:\/\/safegasequipment.co.za\/index.php\/679-2\/","name":"- Safe Gas Equipment Scheme","isPartOf":{"@id":"https:\/\/safegasequipment.co.za\/#website"},"datePublished":"2024-07-31T13:52:35+00:00","dateModified":"2024-07-31T15:54:00+00:00","inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/safegasequipment.co.za\/index.php\/679-2\/"]}]},{"@type":"WebSite","@id":"https:\/\/safegasequipment.co.za\/#website","url":"https:\/\/safegasequipment.co.za\/","name":"Safe Gas Equipment Scheme","description":"","publisher":{"@id":"https:\/\/safegasequipment.co.za\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/safegasequipment.co.za\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/safegasequipment.co.za\/#organization","name":"Safe Gas Equipment Scheme","url":"https:\/\/safegasequipment.co.za\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/safegasequipment.co.za\/#\/schema\/logo\/image\/","url":"https:\/\/safegasequipment.co.za\/wp-content\/uploads\/2019\/07\/cropped-SGES-Logo-TM_web-1.jpg","contentUrl":"https:\/\/safegasequipment.co.za\/wp-content\/uploads\/2019\/07\/cropped-SGES-Logo-TM_web-1.jpg","width":250,"height":186,"caption":"Safe Gas Equipment Scheme"},"image":{"@id":"https:\/\/safegasequipment.co.za\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/safegasequipment.co.za\/index.php\/wp-json\/wp\/v2\/pages\/679"}],"collection":[{"href":"https:\/\/safegasequipment.co.za\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/safegasequipment.co.za\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/safegasequipment.co.za\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/safegasequipment.co.za\/index.php\/wp-json\/wp\/v2\/comments?post=679"}],"version-history":[{"count":3,"href":"https:\/\/safegasequipment.co.za\/index.php\/wp-json\/wp\/v2\/pages\/679\/revisions"}],"predecessor-version":[{"id":685,"href":"https:\/\/safegasequipment.co.za\/index.php\/wp-json\/wp\/v2\/pages\/679\/revisions\/685"}],"wp:attachment":[{"href":"https:\/\/safegasequipment.co.za\/index.php\/wp-json\/wp\/v2\/media?parent=679"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}